Stop Tubes
The Piston Rod Selection Chart on page T3 indicates where
the use of a stop tube should be considered. The required
length of stop tube, where necessary, is read from the
vertical columns on the right of the chart, by following
the horizontal band within which the point of intersection
lies. Note that stop tube requirements differ for fixed
and pivot mounted cylinders.
If the required length of stop tube is in the shaded region
marked consult factory, please submit the following information.
1. Cylinder
mounting style.
2. Rod end connection and method of guiding the load.
3. Bore and stroke required, and length of rod extension
( Dimension ‘K’ ) if greater than standard.
4. Mounting position of cylinder. If at an angle or
vertical, specify the direction of the piston rod.
5. Operating pressure of the cylinder if limited to
less than the standard pressure for the cylinder selected.
When specifying a cylinder
with a stop tube, please state the net stroke of the
cylinder and the length of the stop tube.
|